{"title":"Overvoltage, undervoltage protection relay ","description":"\u003cp\u003e\u003c\/p\u003e","products":[{"product_id":"rele-de-monitorizacao-protecao-trifasico-para-sobretensao-subtensao-controlo-de-sequencia-falha","title":"Three-phase monitoring\/protection relay for overvoltage, undervoltage, sequence\/failure control","description":"\u003cp\u003e\u003cstrong\u003eControl relay - three-phase monitoring\/protection relay for overvoltage, undervoltage, phase failure, phase loss control with timer. GKM-12\/12F (VOLTAGE)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003ePhase protection relays are designed to protect three-phase loads from damage caused by line voltage.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\t\u003cli\u003eVoltage: 230V - 300V AC (adjustable)\u003c\/li\u003e\t\u003cli\u003eUndervoltage: 140V - 210V AC (adjustable)\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003eTimer: 0.1 s - 20 s (adjustable)\u003c\/p\u003e\t\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003ePhase failure protection\u003c\/p\u003e\t\u003c\/li\u003e\t\u003cli\u003ePhase sequence control (GKM-12F)\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003eDIN rail mounting\u003c\/p\u003e\t\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003eWidth 17.8 mm\u003c\/p\u003e\t\u003cp\u003e\u003c\/p\u003e\t\u003cbr\u003e\t\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Yes","offer_id":52247004578125,"sku":"GKV-12F","price":39.24,"currency_code":"EUR","in_stock":false},{"title":"No","offer_id":52247004610893,"sku":"GKV-12","price":40.12,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0894\/0145\/9021\/files\/file_571e1f48-582e-43be-bcfc-50a40a746746.webp?v=1755174076"},{"product_id":"rele-trifasico-de-monitorizacao-protecao-para-controlo-de-sobretensao-e-subtensao","title":"Three-phase monitoring\/protection relay for overvoltage and undervoltage control","description":"\u003ch2 data-start=\"62\" data-end=\"119\"\u003e\u003cstrong data-start=\"65\" data-end=\"119\"\u003e\u003cfont style=\"font-size: 18px;\"\u003eGKM-11 - Single-phase overvoltage and undervoltage relay, TENSO\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-start=\"121\" data-end=\"143\"\u003e\u003cstrong data-start=\"125\" data-end=\"143\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProduct description\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"144\" data-end=\"380\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe GKM-11 relay is used to protect sensitive equipment against overvoltage and undervoltage in single-phase distribution systems. When the set upper or lower voltage limit is exceeded, the relay opens the output contact and disconnects the load, preventing equipment damage.\u003c\/font\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"382\" data-end=\"405\"\u003e\u003cstrong data-start=\"386\" data-end=\"405\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eFunction and operation\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"406\" data-end=\"706\"\u003e\n\u003cli data-start=\"406\" data-end=\"555\"\u003e\n\u003cp data-start=\"408\" data-end=\"429\"\u003e\u003cstrong data-start=\"408\" data-end=\"427\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eStatus indication:\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"432\" data-end=\"555\"\u003e\n\u003cli data-start=\"432\" data-end=\"462\"\u003e\n\u003cp data-start=\"434\" data-end=\"462\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eNormal status - green LED\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"465\" data-end=\"509\"\u003e\n\u003cp data-start=\"467\" data-end=\"509\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eHigh voltage failure - red LED \"HV\"\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"512\" data-end=\"555\"\u003e\n\u003cp data-start=\"514\" data-end=\"555\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eLow voltage error - red LED \"LV\"\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"556\" data-end=\"652\"\u003e\n\u003cp data-start=\"558\" data-end=\"652\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"558\" data-end=\"583\"\u003eAdjustable protection:\u003c\/strong\u003e upper and lower voltage limits, switching delay (DT) and reset time (RT)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"653\" data-end=\"706\"\u003e\n\u003cp data-start=\"655\" data-end=\"706\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"655\" data-end=\"672\"\u003eRelay contact:\u003c\/strong\u003e 5 A \/ 250 V AC (resistive load)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"708\" data-end=\"731\"\u003e\u003cstrong data-start=\"712\" data-end=\"731\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTechnical data\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"732\" data-end=\"1061\"\u003e\n\u003cli data-start=\"732\" data-end=\"771\"\u003e\n\u003cp data-start=\"734\" data-end=\"771\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eOperating voltage: 220 V AC, 50\/60 Hz\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"772\" data-end=\"809\"\u003e\n\u003cp data-start=\"774\" data-end=\"809\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eHigh voltage range: 230-300 V\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"810\" data-end=\"846\"\u003e\n\u003cp data-start=\"812\" data-end=\"846\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eLow voltage range: 150-210 V\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"847\" data-end=\"883\"\u003e\n\u003cp data-start=\"849\" data-end=\"883\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDelay and reset time: 0.5-20 s\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"884\" data-end=\"903\"\u003e\n\u003cp data-start=\"886\" data-end=\"903\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ePower consumption: \u0026lt;6 VA\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"904\" data-end=\"942\"\u003e\n\u003cp data-start=\"906\" data-end=\"942\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eOperating temperature: -20 °C to +55 °C\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"943\" data-end=\"964\"\u003e\n\u003cp data-start=\"945\" data-end=\"964\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMounting: DIN rail\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"965\" data-end=\"985\"\u003e\n\u003cp data-start=\"967\" data-end=\"985\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWeight: 0.1 kg\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"986\" data-end=\"1017\"\u003e\n\u003cp data-start=\"988\" data-end=\"1017\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMaximum cable cross-section: 2.5 mm²\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1018\" data-end=\"1061\"\u003e\n\u003cp data-start=\"1020\" data-end=\"1061\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMaximum installation altitude: 2000 m\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1063\" data-end=\"1078\"\u003e\u003cstrong data-start=\"1067\" data-end=\"1078\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eApplications\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1079\" data-end=\"1184\"\u003e\n\u003cli data-start=\"1079\" data-end=\"1114\"\u003e\n\u003cp data-start=\"1081\" data-end=\"1114\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSingle-phase distribution and equipment\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1115\" data-end=\"1184\"\u003e\n\u003cp data-start=\"1117\" data-end=\"1184\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSensitive electrical equipment, household appliances, industrial machinery\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":52247004741965,"sku":"GKM-11","price":39.68,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0894\/0145\/9021\/files\/20317c23ee072c0847607f7b28061c2c.png?v=1755174078"},{"product_id":"rele-de-monitorizacao-protecao-trifasico-para-sobretensao-subtensao-controlo-de-sequencia-falha-1","title":"Three-phase monitoring\/protection relay for overvoltage, undervoltage, sequence\/failure control","description":"\u003cp\u003e\u003cstrong\u003eThree-phase monitoring\/protection relay for overvoltage, undervoltage, sequence, phase failure control with timer. GKT-03\/03F (ENERGIZED)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003ePhase protection relays are designed to protect three-phase loads from damage caused by line voltage.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\t\u003cli\u003eVoltage: 400 V - 510 V AC (adjustable)\u003c\/li\u003e\t\u003cli\u003eUndervoltage: 260V - 370V AC (adjustable)\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003eTimer: 0.1 s - 20 s (adjustable)\u003c\/p\u003e\t\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003ePhase failure protection\u003c\/p\u003e\t\u003c\/li\u003e\t\u003cli\u003ePhase sequence control (GKT-03F)\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003eDIN rail mounting\u003c\/p\u003e\t\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003eWidth 35.4 mm\u003c\/p\u003e\t\u003cp\u003e\u003c\/p\u003e\t\u003cbr\u003e\t\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Yes","offer_id":52247004840269,"sku":"GKT-03F","price":47.76,"currency_code":"EUR","in_stock":false},{"title":"No","offer_id":52247005135181,"sku":"GKT-03","price":49.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0894\/0145\/9021\/files\/file_3939f7cb-e8d2-4c01-b228-1460d2185f05.png?v=1755174086"},{"product_id":"rele-de-monitorizacao-protecao-trifasico-para-sobretensao-subtensao-controlo-de-sequencia-falha-2","title":"Three-phase monitoring\/protection relay for overvoltage, undervoltage, sequence\/failure control","description":"\u003ch1 data-start=\"184\" data-end=\"249\" style=\"font-family: \" open=\"\" sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"186\" data-end=\"247\" style=\"font-weight: 600;\"\u003e\u003cfont style=\"font-size: 18px;\"\u003eThree-phase voltage control relay - GKM-02\/02F (TENSE)\u003c\/font\u003e\u003c\/span\u003e\u003c\/h1\u003e\u003cp data-start=\"250\" data-end=\"351\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cspan data-start=\"250\" data-end=\"351\" style=\"font-weight: 600;\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eOvervoltage\/undervoltage monitoring - Phase sequence - Zero presence control - 5A output - 140-300 VAC\u003c\/font\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp data-start=\"353\" data-end=\"709\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe three-phase monitoring relay\u003cb\u003e GKM-02\/02F\u003c\/b\u003e from \u003cspan data-start=\"404\" data-end=\"413\" style=\"font-weight: 600;\"\u003eTENSE\u003c\/span\u003e is designed to protect three-phase loads from dangerous state deviations in the power supply network. The device monitors undervoltage, overvoltage, phase loss, incorrect phase sequence, and neutral conductor failure.\u003cbr data-start=\"616\" data-end=\"619\"\u003eWhen a fault is detected, the relay immediately disconnects the output contact, thus protecting the connected equipment.\u003c\/font\u003e\u003c\/p\u003e\u003ch2 data-start=\"716\" data-end=\"741\" style=\"font-family: \" open=\"\" sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"719\" data-end=\"741\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMain features\u003c\/font\u003e\u003c\/span\u003e\u003c\/h2\u003e\u003cul data-start=\"743\" data-end=\"1789\"\u003e\n\u003cli data-start=\"743\" data-end=\"876\"\u003e\u003cp data-start=\"745\" data-end=\"876\"\u003e\u003cspan data-start=\"745\" data-end=\"772\" style=\"font-weight: 600;\"\u003eOvervoltage monitoring (HV):\u003c\/span\u003e\u003cbr data-start=\"772\" data-end=\"775\"\u003e- Reacts to exceeding the set level on any phase\u003cbr data-start=\"835\" data-end=\"838\"\u003e- Adjustment range: \u003cspan data-start=\"860\" data-end=\"876\" style=\"font-weight: 600;\"\u003e230-300 VAC\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"878\" data-end=\"997\"\u003e\u003cp data-start=\"880\" data-end=\"997\"\u003e\u003cspan data-start=\"880\" data-end=\"907\" style=\"font-weight: 600;\"\u003eUndervoltage monitoring (LV):\u003c\/span\u003e\u003cbr data-start=\"907\" data-end=\"910\"\u003e- Reacts to voltage drop on any phase\u003cbr data-start=\"956\" data-end=\"959\"\u003e- Setting range: \u003cspan data-start=\"981\" data-end=\"997\" style=\"font-weight: 600;\"\u003e140-210 V AC\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"999\" data-end=\"1106\"\u003e\u003cp data-start=\"1001\" data-end=\"1106\"\u003e\u003cspan data-start=\"1001\" data-end=\"1035\" style=\"font-weight: 600;\"\u003eAdjustable response time (DT):\u003c\/span\u003e\u003cbr data-start=\"1035\" data-end=\"1038\"\u003e- Delay in response to a fault condition\u003cbr data-start=\"1075\" data-end=\"1078\"\u003e- Range: \u003cspan data-start=\"1090\" data-end=\"1106\" style=\"font-weight: 600;\"\u003e0.1 s - 20 s\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1108\" data-end=\"1228\"\u003e\u003cp data-start=\"1110\" data-end=\"1228\"\u003e\u003cspan data-start=\"1110\" data-end=\"1152\" style=\"font-weight: 600;\"\u003eAutomatic reset - return time (RT):\u003c\/span\u003e\u003cbr data-start=\"1152\" data-end=\"1155\"\u003e- Delay on connection after voltage normalization\u003cbr data-start=\"1197\" data-end=\"1200\"\u003e- range: \u003cspan data-start=\"1212\" data-end=\"1228\" style=\"font-weight: 600;\"\u003e0.1 s - 20 s\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1230\" data-end=\"1355\"\u003e\u003cp data-start=\"1232\" data-end=\"1355\"\u003e\u003cspan data-start=\"1232\" data-end=\"1278\" style=\"font-weight: 600;\"\u003ePhase sequence and phase presence monitoring\u003c\/span\u003e\u003cbr data-start=\"1278\" data-end=\"1281\"\u003e- protection against incorrect phase sequence\u003cbr data-start=\"1328\" data-end=\"1331\"\u003e- phase failure detection\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1357\" data-end=\"1511\"\u003e\u003cp data-start=\"1359\" data-end=\"1511\"\u003e\u003cspan data-start=\"1359\" data-end=\"1407\" style=\"font-weight: 600;\"\u003eNeutral conductor (N) presence monitoring\u003c\/span\u003e\u003cbr data-start=\"1407\" data-end=\"1410\"\u003e- Protection against loss of the N conductor in the network\u003cbr data-start=\"1450\" data-end=\"1453\"\u003e- Disconnection when supply voltage drops below \u003cspan data-start=\"1500\" data-end=\"1511\" style=\"font-weight: 600;\"\u003e88 V AC\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1513\" data-end=\"1591\"\u003e\u003cp data-start=\"1515\" data-end=\"1591\"\u003e\u003cspan data-start=\"1515\" data-end=\"1532\" style=\"font-weight: 600;\"\u003e3% hysteresis\u003c\/span\u003e\u003cbr data-start=\"1532\" data-end=\"1535\"\u003e- limits unwanted fast switching during voltage fluctuations\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1593\" data-end=\"1660\"\u003e\u003cp data-start=\"1595\" data-end=\"1660\"\u003e\u003cspan data-start=\"1595\" data-end=\"1618\" style=\"font-weight: 600;\"\u003eOptical signaling\u003c\/span\u003e\u003cbr data-start=\"1618\" data-end=\"1621\"\u003e- LED indicators for status and fault type\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1662\" data-end=\"1708\"\u003e\u003cp data-start=\"1664\" data-end=\"1708\"\u003e\u003cspan data-start=\"1664\" data-end=\"1708\" style=\"font-weight: 600;\"\u003eCompact design, DIN rail mounting\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1710\" data-end=\"1789\"\u003e\u003cp data-start=\"1712\" data-end=\"1789\"\u003e\u003cspan data-start=\"1712\" data-end=\"1733\" style=\"font-weight: 600;\"\u003eOutput contact:\u003c\/span\u003e\u003cbr data-start=\"1733\" data-end=\"1736\"\u003e- \u003cspan data-start=\"1740\" data-end=\"1751\" style=\"font-weight: 600;\"\u003eNO + NC\u003c\/span\u003e, dry contact\u003cbr data-start=\"1766\" data-end=\"1769\"\u003e- \u003cspan data-start=\"1782\" data-end=\"1789\" style=\"font-weight: 600;\"\u003e5 A\u003c\/span\u003e load\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 data-start=\"1796\" data-end=\"1810\" style=\"font-family: \" open=\"\" sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"1799\" data-end=\"1810\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eApplications\u003c\/font\u003e\u003c\/span\u003e\u003c\/h2\u003e\u003cp data-start=\"1812\" data-end=\"1859\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe relay is designed to protect devices such as\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"1861\" data-end=\"1973\"\u003e\n\u003cli data-start=\"1861\" data-end=\"1881\"\u003e\u003cp data-start=\"1863\" data-end=\"1881\"\u003ethree-phase motors\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1882\" data-end=\"1896\"\u003e\u003cp data-start=\"1884\" data-end=\"1896\"\u003ecompressors\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1897\" data-end=\"1909\"\u003e\u003cp data-start=\"1899\" data-end=\"1909\"\u003epumps\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1910\" data-end=\"1935\"\u003e\u003cp data-start=\"1912\" data-end=\"1935\"\u003eair conditioning units\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1936\" data-end=\"1973\"\u003e\u003cp data-start=\"1938\" data-end=\"1973\"\u003egeneral industrial and domestic loads\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp data-start=\"1975\" data-end=\"1987\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProtects against:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"1989\" data-end=\"2087\"\u003e\n\u003cli data-start=\"1989\" data-end=\"2001\"\u003e\u003cp data-start=\"1991\" data-end=\"2001\"\u003eovervoltage\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2002\" data-end=\"2014\"\u003e\u003cp data-start=\"2004\" data-end=\"2014\"\u003eundervoltage\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2015\" data-end=\"2032\"\u003e\u003cp data-start=\"2017\" data-end=\"2032\"\u003ephase failure\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2033\" data-end=\"2059\"\u003e\u003cp data-start=\"2035\" data-end=\"2059\"\u003eincorrect phase sequence\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2060\" data-end=\"2087\"\u003e\u003cp data-start=\"2062\" data-end=\"2087\"\u003eneutral conductor loss\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 data-start=\"2094\" data-end=\"2120\" style=\"font-family: \" open=\"\" sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"2097\" data-end=\"2120\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIMPORTANT WARNING\u003c\/font\u003e\u003c\/span\u003e\u003c\/h2\u003e\u003cp data-start=\"2122\" data-end=\"2267\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e \u003cspan data-start=\"2125\" data-end=\"2152\" style=\"font-weight: 600;\"\u003eThe relay DOES NOT regulate voltage!\u003c\/span\u003e\u003cbr data-start=\"2152\" data-end=\"2155\"\u003eIt is only used to \u003cem data-start=\"2170\" data-end=\"2187\"\u003edisconnect the load\u003c\/em\u003e during dangerous network conditions, not to stabilize or compensate voltage.\u003c\/font\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Yes","offer_id":52247005266253,"sku":"GKM-02F","price":47.76,"currency_code":"EUR","in_stock":false},{"title":"No","offer_id":52247005299021,"sku":"GKM-02","price":49.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0894\/0145\/9021\/files\/file_af33ffec-8422-4809-aac1-bd96763fe6eb.webp?v=1755174090"},{"product_id":"rele-trifasico-de-monitorizacao-protecao-para-controlo-de-sobretensao-subtensao-sequencia-de-assimetria","title":"Three-phase monitoring\/protection relay for overvoltage, undervoltage, and asymmetry sequence control","description":"\u003cdiv\u003e\n\u003ch1 data-start=\"226\" data-end=\"290\"\u003e\u003cstrong data-start=\"228\" data-end=\"290\"\u003e\u003cfont style=\"font-size: 18px;\"\u003eTENSE phase protection relay - adjustable asymmetry 5-50%\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp data-start=\"292\" data-end=\"616\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe phase protection relay from \u003cstrong data-start=\"328\" data-end=\"347\"\u003eTENSE (Turkey)\u003c\/strong\u003e is designed to protect three-phase electric motors and other three-phase equipment from power supply network faults. The device checks the \u003cstrong data-start=\"477\" data-end=\"498\"\u003ecorrect phase sequence\u003c\/strong\u003e, \u003cstrong data-start=\"500\" data-end=\"518\"\u003ephase asymmetry\u003c\/strong\u003e, \u003cstrong data-start=\"520\" data-end=\"531\"\u003eundervoltage\u003c\/strong\u003e, \u003cstrong data-start=\"533\" data-end=\"544\"\u003eovervoltage\u003c\/strong\u003e, and ensures safe disconnection of the load when set limits are exceeded.\u003c\/font\u003e\u003c\/p\u003e\n\u003cp data-start=\"618\" data-end=\"777\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe wide range of settings makes the relay suitable for most industrial and commercial applications, especially when precise and stable motor protection is required.\u003c\/font\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"784\" data-end=\"809\"\u003e\u003cstrong data-start=\"787\" data-end=\"809\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMain features\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"810\" data-end=\"1250\"\u003e\n\u003cli data-start=\"810\" data-end=\"872\"\u003e\n\u003cp data-start=\"812\" data-end=\"872\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"812\" data-end=\"835\"\u003ePhase sequence control\u003c\/strong\u003e - protection against incorrect connections.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"873\" data-end=\"914\"\u003e\n\u003cp data-start=\"875\" data-end=\"914\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"875\" data-end=\"913\"\u003eAdjustable asymmetry: 5% - 50%\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"915\" data-end=\"956\"\u003e\n\u003cp data-start=\"917\" data-end=\"956\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"917\" data-end=\"955\"\u003eAdjustable undervoltage: 260-360 VAC\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"957\" data-end=\"998\"\u003e\n\u003cp data-start=\"959\" data-end=\"998\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"959\" data-end=\"997\"\u003eAdjustable overvoltage: 400-480 VAC\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"999\" data-end=\"1055\"\u003e\n\u003cp data-start=\"1001\" data-end=\"1055\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1001\" data-end=\"1054\"\u003eAdjustable error delay time (Err In): 1-30 s\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1056\" data-end=\"1105\"\u003e\n\u003cp data-start=\"1058\" data-end=\"1105\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1058\" data-end=\"1104\"\u003eAdjustable recovery time (Err OUT): 1-30 s\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1106\" data-end=\"1159\"\u003e\n\u003cp data-start=\"1108\" data-end=\"1159\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eClear indication on the \u003cstrong data-start=\"1130\" data-end=\"1158\"\u003e3×3 segment display\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1160\" data-end=\"1212\"\u003e\n\u003cp data-start=\"1162\" data-end=\"1212\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eHigh accuracy and fast response to network faults.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1213\" data-end=\"1250\"\u003e\n\u003cp data-start=\"1215\" data-end=\"1250\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eStandard \u003cstrong data-start=\"1236\" data-end=\"1249\"\u003eDIN rail\u003c\/strong\u003e mounting.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1257\" data-end=\"1281\"\u003e\u003cstrong data-start=\"1260\" data-end=\"1281\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eOperating principles\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-start=\"1283\" data-end=\"1306\"\u003e\u003cstrong data-start=\"1287\" data-end=\"1306\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eNormal operation\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1307\" data-end=\"1372\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWhen all phase voltages are within limits and the phase sequence is correct:\u003c\/font\u003e\u003c\/p\u003e\n\u003cul data-start=\"1373\" data-end=\"1407\"\u003e\n\u003cli data-start=\"1373\" data-end=\"1386\"\u003e\n\u003cp data-start=\"1375\" data-end=\"1386\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ethe relay trips,\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1387\" data-end=\"1407\"\u003e\n\u003cp data-start=\"1389\" data-end=\"1407\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe \u003cstrong data-start=\"1393\" data-end=\"1400\"\u003eOUT\u003c\/strong\u003e LED lights up.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1414\" data-end=\"1447\"\u003e\u003cstrong data-start=\"1418\" data-end=\"1447\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eHigh voltage error (H)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1448\" data-end=\"1646\"\u003e\n\u003cli data-start=\"1448\" data-end=\"1530\"\u003e\n\u003cp data-start=\"1450\" data-end=\"1530\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIf the phase exceeds the set limit → the \u003cstrong data-start=\"1501\" data-end=\"1511\"\u003eErr In\u003c\/strong\u003e time is pending, \u003cstrong data-start=\"1524\" data-end=\"1529\"\u003eH\u003c\/strong\u003e is displayed.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1531\" data-end=\"1559\"\u003e\n\u003cp data-start=\"1533\" data-end=\"1559\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe relay switches off, OUT turns off.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1560\" data-end=\"1646\"\u003e\n\u003cp data-start=\"1562\" data-end=\"1646\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWhen 5 V drops below the set value, \u003cstrong data-start=\"1614\" data-end=\"1625\"\u003eErr OUT\u003c\/strong\u003e starts, the relay switches on again.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1653\" data-end=\"1685\"\u003e\u003cstrong data-start=\"1657\" data-end=\"1685\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eLow voltage error (L)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1686\" data-end=\"1845\"\u003e\n\u003cli data-start=\"1686\" data-end=\"1753\"\u003e\n\u003cp data-start=\"1688\" data-end=\"1753\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDrop below the set limit → \u003cstrong data-start=\"1724\" data-end=\"1734\"\u003eErr Em\u003c\/strong\u003e waiting, \u003cstrong data-start=\"1747\" data-end=\"1752\"\u003eL\u003c\/strong\u003e is displayed.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1754\" data-end=\"1770\"\u003e\n\u003cp data-start=\"1756\" data-end=\"1770\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe relay switches off.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1771\" data-end=\"1845\"\u003e\n\u003cp data-start=\"1773\" data-end=\"1845\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWhen voltage rises 5 V above the threshold → Err \u003cstrong data-start=\"1815\" data-end=\"1826\"\u003eOUT\u003c\/strong\u003e waiting, the relay activates.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1852\" data-end=\"1880\"\u003e\u003cstrong data-start=\"1856\" data-end=\"1880\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ePhase asymmetry (Asy)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1881\" data-end=\"2093\"\u003e\n\u003cli data-start=\"1881\" data-end=\"2006\"\u003e\n\u003cp data-start=\"1883\" data-end=\"1948\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIf the voltage difference between phases exceeds the set threshold (5-50%):\u003c\/font\u003e\u003c\/p\u003e\n\u003cul data-start=\"1951\" data-end=\"2006\"\u003e\n\u003cli data-start=\"1951\" data-end=\"2006\"\u003e\n\u003cp data-start=\"1953\" data-end=\"2006\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e \u003cstrong data-start=\"1983\" data-end=\"1990\"\u003eASy\u003c\/strong\u003e is displayed after the \u003cstrong data-start=\"1961\" data-end=\"1971\"\u003eErr In\u003c\/strong\u003e time, the relay is deactivated.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2007\" data-end=\"2093\"\u003e\n\u003cp data-start=\"2009\" data-end=\"2093\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWhen asymmetry is reduced to less than (set threshold - 2%) → wait time \u003cstrong data-start=\"2066\" data-end=\"2077\"\u003eErr OUT\u003c\/strong\u003e, the relay switches on.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2100\" data-end=\"2130\"\u003e\u003cstrong data-start=\"2104\" data-end=\"2130\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ePhase sequence error (pHs)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2131\" data-end=\"2333\"\u003e\n\u003cli data-start=\"2131\" data-end=\"2204\"\u003e\n\u003cp data-start=\"2133\" data-end=\"2204\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWhen a phase sequence error occurs, the relay waits for \u003cstrong data-start=\"2171\" data-end=\"2181\"\u003eErr In\u003c\/strong\u003e and then displays \u003cstrong data-start=\"2196\" data-end=\"2203\"\u003epHs\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2205\" data-end=\"2271\"\u003e\n\u003cp data-start=\"2207\" data-end=\"2271\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe relay switches off and remains off until the correct sequence is restored.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2272\" data-end=\"2333\"\u003e\n\u003cp data-start=\"2274\" data-end=\"2333\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAfter the phase sequence is corrected, \u003cstrong data-start=\"2305\" data-end=\"2316\"\u003eErr OUT\u003c\/strong\u003e occurs and the relay switches on.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2335\" data-end=\"2338\"\u003e\n\u003ch2 data-start=\"2340\" data-end=\"2366\"\u003e\u003cstrong data-start=\"2343\" data-end=\"2366\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTechnical parameters\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\u003cdiv tabindex=\"-1\" class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\"\u003e\u003ctable data-start=\"2368\" data-end=\"2982\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2368\" data-end=\"2390\"\u003e\u003ctr data-start=\"2368\" data-end=\"2390\"\u003e\n\u003cth data-start=\"2368\" data-end=\"2379\" data-col-size=\"sm\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eParameter\u003c\/font\u003e\u003c\/th\u003e\n\u003cth data-start=\"2379\" data-end=\"2390\" data-col-size=\"sm\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eParameter value\u003c\/font\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody data-start=\"2413\" data-end=\"2982\"\u003e\n\u003ctr data-start=\"2413\" data-end=\"2458\"\u003e\n\u003ctd data-start=\"2413\" data-end=\"2440\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2415\" data-end=\"2439\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eOperating voltage (Un)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2440\" data-end=\"2458\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e3×380 V AC + N\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2459\" data-end=\"2487\"\u003e\n\u003ctd data-start=\"2459\" data-end=\"2475\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2461\" data-end=\"2474\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eFrequency\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2475\" data-end=\"2487\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e50\/60 Hz\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2488\" data-end=\"2511\"\u003e\n\u003ctd data-start=\"2488\" data-end=\"2501\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2490\" data-end=\"2500\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ePower input\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2501\" data-end=\"2511\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003c 6 VA\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2512\" data-end=\"2552\"\u003e\n\u003ctd data-start=\"2512\" data-end=\"2532\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2514\" data-end=\"2531\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAmbient temperature\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2532\" data-end=\"2552\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e-20 °C to +55 °C\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2553\" data-end=\"2596\"\u003e\n\u003ctd data-start=\"2553\" data-end=\"2580\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2555\" data-end=\"2579\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eHigh voltage threshold\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2580\" data-end=\"2596\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e400-480 V AC\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2597\" data-end=\"2639\"\u003e\n\u003ctd data-start=\"2597\" data-end=\"2623\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2599\" data-end=\"2622\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eLow voltage threshold\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2623\" data-end=\"2639\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e260-360 V AC\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2640\" data-end=\"2681\"\u003e\n\u003ctd data-start=\"2640\" data-end=\"2656\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2642\" data-end=\"2655\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAsymmetry\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2656\" data-end=\"2681\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e5-50% (adjustable)\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2682\" data-end=\"2718\"\u003e\n\u003ctd data-start=\"2682\" data-end=\"2708\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2684\" data-end=\"2707\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eError time (Err In)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2708\" data-end=\"2718\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e1-30 s\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2719\" data-end=\"2757\"\u003e\n\u003ctd data-start=\"2719\" data-end=\"2747\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2721\" data-end=\"2746\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eReset time (Err OUT)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2747\" data-end=\"2757\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e1-30 s\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2758\" data-end=\"2814\"\u003e\n\u003ctd data-start=\"2758\" data-end=\"2777\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2760\" data-end=\"2776\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eRelay contact\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2777\" data-end=\"2814\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e5 A \/ 250 V AC (resistive load)\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2815\" data-end=\"2852\"\u003e\n\u003ctd data-start=\"2815\" data-end=\"2829\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2817\" data-end=\"2828\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDisplay\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2829\" data-end=\"2852\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e3×3 segments, 1 LED\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2853\" data-end=\"2879\"\u003e\n\u003ctd data-start=\"2853\" data-end=\"2866\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2855\" data-end=\"2865\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMounting\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2866\" data-end=\"2879\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDIN rail\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2880\" data-end=\"2906\"\u003e\n\u003ctd data-start=\"2880\" data-end=\"2895\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2882\" data-end=\"2894\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWeight\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2895\" data-end=\"2906\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003c 150 g\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2907\" data-end=\"2947\"\u003e\n\u003ctd data-start=\"2907\" data-end=\"2935\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2909\" data-end=\"2934\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMaximum installation height\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2935\" data-end=\"2947\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003c 2000 m\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2948\" data-end=\"2982\"\u003e\n\u003ctd data-start=\"2948\" data-end=\"2968\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2950\" data-end=\"2967\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eCable cross-section\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2968\" data-end=\"2982\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eup to 2.5 mm²\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cul\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":52247008084301,"sku":"FKV-03HF","price":35.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0894\/0145\/9021\/files\/832dc14996d8a591923779b140e90b0f.png?v=1755174203"}],"url":"https:\/\/pelek.pt\/en\/collections\/ochranne-rele-proti-prepeti-podpeti.oembed","provider":"PELEK_PT","version":"1.0","type":"link"}